[E-BC-K207-S] Sodium (Na) Colorimetric Assay Kit 요약정보 및 구매

R1:20mL×2,R2:10mL×2

상품 선택옵션 0 개, 추가옵션 0 개

제조사 Elabscience
납기일 1-2 주
판매가격 210,000원
포인트 0점(구매금액 : 0%)
배송비결제 3,500원   (주문금액 10만원 이상일시 배송비 무료)

선택된 옵션

  • [E-BC-K207-S] Sodium (Na) Colorimetric Assay Kit (+0원)

상품 정보

상품 기본설명

R1:20mL×2,R2:10mL×2

상품 상세설명

Application

This kit can be used for detecting the concentration of sodium ions in serum or plasma samples. 

 

Detection principle

Production of o-nitrophenol and galactose by o-nitrophenol-β-D-galactoside(ONPG) catalyzed by sodium dependent β-D-galactosidase. The amount of o-nitrophenol is directly proportional to the concentration of sodium ion in the sample. The o-nitrophenol is yellow in alkaline environment. The increase of absorbance is determined at 405nm, and the content of sodium ion is calculated indirectly.

 

Experiment instruments

Spectrophotometer (405 nm), Biochemical analyzer (405 nm), Microplate reader(405 nm), Micropipettor  

 

Sample requirement

Separate the serum or plasma as soon as possible after blood collection to avoid hemolysis.

 

Operation steps

1.    Detection with Microplate reader:


 

Blank

Standard

Sample 

ddH2O (μL)

8

 

 

Standard (μL)

 

8

 

Sample (μL)

 

 

8

Reagent 1 (μL) 

200

200

200

Reagent 2 (μL)

100

100

100

Mix fully and stand for 1 min. Measure the absorbance at 405 nm at 0 min (A1) and 2 min (A2), respectively. 

  

2.    Detection with spectrophotometer:

 

Blank

Standard

Sample

ddH2O (μL)

32

 

 

Standard (μL)

 

32

 

Sample (μL) 

 

 

32

Reagent 1 (μL) 

800

800

800

Reagent 2 (μL) 

400

400

400

Mix fully and stand for 1 min. Set to zero with ddH2O, measure the absorbance of each tube with 1 cm cuvette at 405 nm at 0 min (A1) and 2 min (A2), respectively. 

 

3.    Detection with biochemical analyzer: input the parameters follow the table.

Analysis method

Two-point method 

Wavelength (nm) 

405

Reaction direction

Up

Sample (μL) 

8

Reagent 1 (μL) 

200

Reagent 2 (μL)

100

Delay time (min)

1

Reaction time (min)

2



 

Relevant parameters

1.  Absorbance of blank: A405 ≤ 0.5, △A405 ≤0.4 (optical path = 1 cm)

2.  Linear range: 80~180 μmol/L, |R| 0.995.

3.  Sensitivity: (|△A|/min) is between 0.0011 ~ 0.0036 when testing 140 mmol/L samples.

4.  Accuracy: relative deviation ≤ 10%

5.  Precision: intra-CV≤ 5.0%inter- CV ≤ 8%.

 

Notes

1.  This kit is for research use only.

2.  Please operate strictly according to operation procedures.

3.  Do not use expired kit or reagents of different batches.

4.  Please take safety precautions and follow the procedures of laboratory reagent operation. All waste liquid should be handled in accordance with local regulations. 

상품문의

등록된 상품문의

상품문의가 없습니다.

반품/교환정보

셀젠바이오샵에서는 다음과 같은 기간 및 내용으로 상품에 대하여 교환, 반품, 환불을 보장하고 있으며, 상품의 반환에 의한

추가비용을 고객에게 부담시지키 않습니다. (, 고객 변심 또는 주문 반복으로 인한 경우의 반환비용은 고객님이 부담하셔야

합니다.)

 

::: 교환 및 반품이 가능한 경우:::

-상품을 공급 받으신 날로부터 7일 이내

  , 상품을 개봉하여 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.

-공급받으신 상품 및 용역의 내용이 표시, 광고 내용과 다르거나 다르게 이행된 경우
-

:::교환 및 반품이 불가능한 경우:::

-하자가 없는 상품을 택배사로부터 인도 받으신 날로부터 20일 이후.
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우.
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 현저히 감소한 경우
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
- 주문 당시 해외 발주 상품의 경우
-

주문 취소 및 반품으로 환불을 요청하실 경우에는 E-mail(celgen-bio@celgen-bio.com)이나 고객만족센터 (042-824-9026)

통해 요청하시면 친절하게 처리해 드리겠습니다.

주문 취소 후 반품 가능 여부를 확인한 다음 3일 이내에 결제 금액을 환불해 드리겠습니다.
  • ㈜셀젠바이오테크, 대표자명: 김성빈, 사업자등록번호: 344-08-00018, 통신판매업종 제 2017-대전유성-0220 호
  • 대전광역시 대덕구 대화로69, 3층(대화동)
  • 대표전화: 042-824-9026 팩스: 042-824-9027
  • E-Mail: celgen-bio@celgen-bio.com
  • Copyright © 2015 Celgen-Bio.tech All rights reserved.