This CLIA kit applies to the in vitro quantitative determination of Human sICAM-1/CD54 concentrations in serum, plasma and other biological fluids.
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human sICAM-1/CD54. Standards or samples are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human sICAM-1/CD54 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human sICAM-1/CD54, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human sICAM-1/CD54. You can calculate the concentration of Human sICAM-1/CD54 in the samples by comparing the RLU value of the samples to the standard curve.
Assay type | Sandwich |
Format | 96T |
Assay time | 3.5h |
Reactivity | Human |
Detection method | Chemiluminescence |
Detection range | 31.25-2000 pg/mL |
Sensitivity | 18.75 pg/mL |
Sample volume | 100μL |
Sample type | Serum, plasma and other biological fluids |
Repeatability | CV < 15% |
This kit recognizes Human sICAM-1/CD54 in samples. No significant cross-reactivity or interference between Human sICAM-1/CD54 and analogues was observed.
As the RLU values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (pg/mL) | RLU | Average | Corrected |
---|---|---|---|
2000 | 53526 57916 | 55721 | 55693 |
1000 | 22688 25260 | 23974 | 23946 |
500 | 11782 10282 | 11032 | 11004 |
250 | 4829 5759 | 5294 | 5266 |
125 | 2658 2558 | 2608 | 2580 |
62.5 | 1327 1295 | 1311 | 1283 |
31.25 | 664 684 | 674 | 646 |
0 | 27 29 | 28 | -- |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human sICAM-1/CD54 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human sICAM-1/CD54 were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 95.67 | 314.58 | 684.45 | 94.08 | 340.00 | 647.71 |
Standard deviation | 9.19 | 36.52 | 71.18 | 12.07 | 38.05 | 57.84 |
C V (%) | 9.61 | 11.61 | 10.40 | 12.83 | 11.19 | 8.93 |
The recovery of Human sICAM-1/CD54 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum (n=5) | 89-102 | 96 |
EDTA plasma (n=5) | 91-106 | 98 |
Cell culture media (n=5) | 89-101 | 96 |
Samples were spiked with high concentrations of Human sICAM-1/CD54 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
---|---|---|---|---|
1:2 | Range (%) | 93-106 | 91-108 | 92-104 |
Average (%) | 99 | 99 | 99 | |
1:4 | Range (%) | 87-99 | 102-119 | 98-111 |
Average (%) | 94 | 108 | 104 | |
1:8 | Range (%) | 97-113 | 97-110 | 98-112 |
Average (%) | 103 | 104 | 105 | |
1:16 | Range (%) | 90-107 | 96-112 | 96-110 |
Average (%) | 97 | 104 | 102 |
An unopened kit can be stored at 2-8℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
---|---|---|
Micro CLIA Plate(Dismountable) | 8 wells ×12 strips | -20℃, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 μL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 μL | -20℃(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8℃, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (shading light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (shading light) |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Note: All reagent bottle caps must be tightened to prevent evaporation and microbial pollution.
The volume of reagents in partial shipments is a little more than the volume marked on the label, please use accurate measuring equipment instead of directly pouring into the vial(s).
1.Add 100 μL of standard or sample to each well. Incubate for 90 min at 37℃. | |
2.Remove the liquid. | |
3.Add 100 μL Biotinylated Detection Ab. Incubate 1 hour at 37℃. Aspirate and wash 3 times. | |
4.Add 100 μL HRP Conjugate. Incubate 30 min at 37℃. Aspirate and wash 5 times. | |
5.Add 100 μL Substrate Mixture Solution. Incubate for 5 min at 37℃. | |
6.Fluorescence appeared. Measure the RLU value with the Chemiluminescence immunoassay analyzer. Calculation of the results. |
상품문의가 없습니다.
추가비용을 고객에게 부담시지키 않습니다. (단, 고객 변심 또는 주문 반복으로 인한 경우의 반환비용은 고객님이 부담하셔야
합니다.)
::: 교환 및 반품이 가능한 경우:::
단, 상품을 개봉하여 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.
:::교환 및 반품이 불가능한 경우:::
주문 취소 및 반품으로 환불을 요청하실 경우에는 E-mail(celgen-bio@celgen-bio.com)이나 고객만족센터 (042-824-9026)을
통해 요청하시면 친절하게 처리해 드리겠습니다.
주문 취소 후 반품 가능 여부를 확인한 다음 3일 이내에 결제 금액을 환불해 드리겠습니다.