[E-BC-K070-S] Nitrite Colorimetric Assay Kit 요약정보 및 구매

100Assays

상품 선택옵션 0 개, 추가옵션 0 개

제조사 Elabscience
납기일 1-2 주
판매가격 210,000원
포인트 0점(구매금액 : 0%)
배송비결제 3,500원   (주문금액 10만원 이상일시 배송비 무료)

선택된 옵션

  • [E-BC-K070-S] Nitrite Colorimetric Assay Kit (+0원)

상품 정보

상품 기본설명

100Assays

상품 상세설명

 

General information

Detection significance


Nitrite and nitrate are important chemical components in almost all living organisms. In vivo, nitrite and nitrate come from the NO oxidation pathway without excessive uptake of nitrite and nitrate.

Detection principle


Nitrite can react with chromogenic agent producing light red azo-compound. The content of nitrite can be calculated indirectly by measuring the OD value at 550 nm.

The key point


The supernatant for chromogenic reaction should not contain sediment, otherwise it will affect the results.

Operation procedures

Operation steps


1.    Blank tube: Add a* mL of Double distilled water into a 2 mL EP tube.

Standard tube: Add a* mL of 100 μmol/L Sodium nitrite standard solution into a 2 mL EP tube.

Sample tube: Add a* mL of Sample into a 2 mL EP tube.

(a* = volume of sample = volume of standard = volume of double distilled water.)

(Reference sampling quantity: 0.2~0.4 mL for serum (plasma) and 0.1~0.2 mL for tissue or cells homogenate.)

2.    Add 0.8 mL of Reagent 1 and oscillate fully with vortex mixer.

3.    Add 0.4 mL of Reagent 2 and oscillate fully with vortex mixer.

4.    Stand the tubes at room temperature for 10 min and centrifuge at 2000 g for 10 min. (The supernatant after centrifugation must be clarified, and if there is precipitate, it must be centrifuged again.)

5.    Take 0.8 mL of supernatant into a 2 mL EP tube, add 0.4 mL of Chromogenic agent.

6.    Mix fully and stand the tubes at room temperature for 15 min. Set to zero with double distilled water and measure the OD values of each tube at 550 nm with 0.5 cm diameter cuvette.

Operation table


 

 

Blank tube

Standard tube

Sample tube

Double distilled water (mL) 

a* 

 

 

100 μmol/L sodium nitrite standard solution (mL) 

 

a* 

 

Sample (mL) 

 

 

a* 

Reagent 1 (mL) 

0.8

0.8

0.8

Reagent 2 (mL) 

0.4

0.4

0.4

Mix fully and stand for 10 min at room temperature, centrifuge at 2000 g for 10 min, take the supernatant for detection.

Supernatant (mL) 

0.8

0.8

0.8

Chromogenic agent (mL) 

0.4

0.4

0.4

Mix fully and stand the tubes at room temperature for 15 min. Set to zero with double distilled water and measure the OD values of each tube at 550 nm with 0.5 cm diameter cuvette.

Performance characteristics

Technical parameter



Detection range1.36-500 μmol/LAverage inter-assay CV3.3%
Sensitivity1.36 μmol/LAverage intra-assay CV2.6%
Average recovery rate97% 

 

상품문의

등록된 상품문의

상품문의가 없습니다.

반품/교환정보

셀젠바이오샵에서는 다음과 같은 기간 및 내용으로 상품에 대하여 교환, 반품, 환불을 보장하고 있으며, 상품의 반환에 의한

추가비용을 고객에게 부담시지키 않습니다. (, 고객 변심 또는 주문 반복으로 인한 경우의 반환비용은 고객님이 부담하셔야

합니다.)

 

::: 교환 및 반품이 가능한 경우:::

-상품을 공급 받으신 날로부터 7일 이내

  , 상품을 개봉하여 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.

-공급받으신 상품 및 용역의 내용이 표시, 광고 내용과 다르거나 다르게 이행된 경우
-

:::교환 및 반품이 불가능한 경우:::

-하자가 없는 상품을 택배사로부터 인도 받으신 날로부터 20일 이후.
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우.
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 현저히 감소한 경우
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
- 주문 당시 해외 발주 상품의 경우
-

주문 취소 및 반품으로 환불을 요청하실 경우에는 E-mail(celgen-bio@celgen-bio.com)이나 고객만족센터 (042-824-9026)

통해 요청하시면 친절하게 처리해 드리겠습니다.

주문 취소 후 반품 가능 여부를 확인한 다음 3일 이내에 결제 금액을 환불해 드리겠습니다.
  • ㈜셀젠바이오테크, 대표자명: 김성빈, 사업자등록번호: 344-08-00018, 통신판매업종 제 2017-대전유성-0220 호
  • 대전광역시 대덕구 대화로69, 3층(대화동)
  • 대표전화: 042-824-9026 팩스: 042-824-9027
  • E-Mail: celgen-bio@celgen-bio.com
  • Copyright © 2015 Celgen-Bio.tech All rights reserved.